your people, your assets, and your reputation, with the only fail-safe, fully-integrated fire-suppression range hood for UL300A applications
With the industry’s first and only fully integrated, mechanically actuated (fail-safe), pre-engineered, fire suppression range hood system specifically engineered for domestic-grade stove-tops in limited commercial settings.

The D1000 fulfills all of the theory and intent behind a Type I commercial hood with fire suppression in a product designed for use over a residential-grade cooktop. The D1000 is perfect for any commercial space that uses a residential-grade appliance in a “not for profit” cooking application.

Specify Safety

  • Fail-Safe Mechanical Mechanism
  • ETL Listed
  • UL300A Compliant
  • NFPA101

Specify with Confidence

  • Manufactured in the USA
  • Mechanical Fail-Safe actuation
  • Over 15 years of developments in the UL300A market.
D1030 (30") Complete Submittals
Recirculating Fan, Front Discharge
Rear Discharge, Integral Fan
Top Discharge, External – Inline Fan
Top Discharge, Roof Mounted Fan
Top Discharge, Wall Mounted Fan
D1036 (36") Complete Submittals
Recirculating Fan, Front Discharge
Rear Discharge, Integral Fan
Top Discharge, External – Inline Fan
Top Discharge, External – Inline Fan
Top Discharge, Wall Mounted Fan
How It Works
  1. Heat builds and first set point is reached
  2. Fan will turn on high to dissipate the heat
  3. If the heat continues to build, a second switch is activated
  4. The fuel source to the range is shut-off
  5. An audible internal alarm sounds
  6. If heat continues, the fusible link reaches set point
  7. The mechanical (fail-safe) discharge of the suppression system is activated [manual activation also available]
  8. Fire is extinguished
Code Official Details

Code Official Details

ICC-ES PMG Product Certificate  PMG-1122

Effective Date: June 2023

Click here for PDF download.

Effective July 1, 2012, The D1000 became the only system recognized for use by the ICC.  The D1000 is an ICC/ES PMG-listed product, garnering immediate code approval in most jurisdictions. Certain applications automatically comply with the ’09 & ’12 IMC, UMC & IFC. 

Effective January 1, 2013, The D1000 became the basis of design behind the 2012 Amendment to the NFPA Life Safety Code.  This new code language makes the D1000 A REQUIREMENT in all residential health care facilities. 

The D1000 by DENLAR Fire Protection is the industry’s first fully integrated, pre-engineered fire suppression range hood system. The D1000 fulfills all of the theory and intent behind a type 1 commercial hood with fire suppression (NFPA 96, 17A & UL/ETL 300) in a product designed for use over a residential-grade appliance.  Products in this category are listed to UL/ETL 300A – these types of systems are intended to be used within a commercial space, when a residential-grade appliance is used in a “not for profit” cooking application.

The D1000 also includes an environmental monitoring system, designed to interact with the cooking environment and minimize the likelihood of a fire event.  This is a two-stage temperature monitoring system.  At a mid-temperature set point, the system will automatically engage the fan on high to dissipate heat from the area.  At a high-temperature set point, the system will preemptively disconnect the cooking element to the appliance before suppression system release.  If these two stages of “pre-suppression” do not stem the tide of a growing fire event, the fusible links will melt, causing the system to actuate mechanically – consistent with other commercial fire suppression systems.

This same internal monitoring system also addressed the entire suppression assembly.  If it is ever compromised in any way (tampering, loss of pressure, etc.) the system reacts by shutting down the cooking element and in this case, creates a separate “maintenance code”, alerting the maintenance staff and avoiding a typical “trouble alarm”.  The D1000 will not only automatically suppress a cooking fire event – it will work to minimize overall fire risk in the space.  Engineers, designers, facilities managers, and code officials should be confident in recommending and approving The D1000 in all applications where a residential-grade appliance is used in a “not for profit” capacity within a commercial space.

  • Sizes: 30″ (D1030) & 36″ (D1036)
  • Ducting Calibrations: Front Recirculating (F, internal fan), Rear Expelling (R, internal fan), Vertically Ducted (I, two remote fan options)
  • Range Element Disconnect Modules: Electric (E), Gas (G), Dual-Element (DED)
  • Options: Manual Pull Station (MPK), The ClockBox (CLBX), Handicapped Accessible Controls (ADA), NSF Upgrade (NSF), Powder Coating (PC),
  • NFPA101 Packaged Upgrade* (NFPA101)

*Packaged upgrade includes the following features & add-ons: Manual Pull Station, The ClockBox, and an upgraded fan to achieve 500cfm.

Product Configurator

Model Number Selection

Select a 

  • Model
  • Fan Type
  • Fuel Disconnect
  • and Optional Accessories
We use cookies to personalise content and ads, to provide social media features and to analyse our traffic. We also share information about your use of our site with our social media, advertising and analytics partners. View more
Cookies settings
Accept
Privacy & Cookie policy
Privacy & Cookies policy
Cookie name Active

Introduction

This Privacy Policy outlines Denlar Fire Protection, LLC (" we ", " our " or " the Company ") practices with respect to information collected from users who access our website at denlarhoods.com (" Site "), or otherwise share personal information with us (collectively: " Users "). 

Cookies

We and our trusted partners use cookies and other technologies in our related services, including when you visit our Site or access our services. 

Cookies do not contain any information that personally identifies you, but Personal Information that we store about you may be linked, by us, to the information stored in and obtained from cookies. You may remove the cookies by following the instructions of your device preferences; however, if you choose to disable cookies, some features of our Site may not operate properly and your online experience may be limited.

We also use Google Analytics, HubSpot, and ZoomInfo to collect information about your use of the Site.

These sites collect information such as how often users access our site, what pages they visit when they do so, etc. We use the information we get from these sources to improve your experience of working with Denlar Fire Protection and our Representatives, as well as making improvements to our website.

These sites also collect the IP address assigned to you on the date you visit sites, and in some cases the URL of the company assigned to that IP address rather than your name or other personal identifying information.

If you choose to use the added functionality of our site, you will be asked to provide your name and email address and that information will be used by Denlar Fire Protection to keep you informed of the progress of orders, new developments in our products, or other marketing, sales, and service uses. It will not be sold, traded, shared, or rented to any user outside of our collaborative companies: Chapco, inc. and Fastcorp Vending LLC.

If you have any questions or comments about our site, please contact us through our webform HERE

Save settings
Cookies settings